| NJT8319F Specifications | |
|---|---|
| RF Frequency | 14.0 - 14.50 GHz |
| L.O. Frequency | 13.05 GHz |
| Output Power @ P1dB | 16W Linear (+42 dBm min.) |
| IF Connector | N-Type Female |
| Voltage Input Port | MS Connector |
| FSK Communication M&C | |
| Linear Gain | 68 dB nom., 62 dB min. |
| Gain Variation over frequency | 5 dBp-p max. over 750 MHz / 2 dBp-p max. over 36 MHz |
| Gain Stability over temperature | 2 dBp-p typ., 5 dBp-p max. |
| IM3 | -28 dBc typ., -24 dBc max. @ total power ≤Pout – 3dB |
| ACPR | -28 dBc typ. @ Pout ≤Pout – 1dB |
| L.O. Phase Noise | -60 dBc/Hz max. @ 100 Hz -70 dBc/Hz max. @ 1 kHz -80 dBc/Hz max. @ 10 kHz -90 dBc/Hz max. @ 100 kHz -100 dBc/Hz max. @ 1 MHz |
| Input V.S.W.R. | 2 : 1 max. |
| Output V.S.W.R. | 2 : 1 max. |
| DC Power Requirement (1) Voltage Range (2) Power Consumption @ No IF Signal @ P1dB |
+36 to +60 VDC
140 W typ. |
| Mute | Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal |
| LED Indicator | GREEN: L.O. locked / RED: L.O. unlocked (or no 10 MHz reference signal) |
| M&C Function | FSK Modulation M&C: Power Monitor / TX On/Off Control / Alarm … etc |
| Temperature Range (ambient) Operating Storage |
-40 to +75 C (Operation Guarantee) -40 to +55 C (Performance Guarantee) -40 to +75 C |
| Dimension & Housing | 180 (L) x 130 (W) x 80 (H) mm [7.09” (L) x 5.12” (W) x 3.15” (H)] without interface connector and screws |
| Weight | 2.4 kg max. [5.3 lbs max.] |