Item | Specifications |
Saturation Output Power | +46 dBm min. @ +25 °C / +45 dBm min. over temperature |
Linear Gain | 72 dB nom., 66 dB min. |
Gain Variation over frequency
Standard Ku-band: Universal Ku-band: |
5 dBp-p max. over 500 MHz / 2 dBp-p max. over 54 MHz
5 dBp-p max. over 750 MHz / 2 dBp-p max. over 54 MHz |
Gain Stability over temperature | 2 dBp-p typ., 4 dBp-p max. |
ACPR | -30 dBc typ., -26 dBc min. @ Pout = +44 dBm |
L.O. Phase Noise | -60 dBc/Hz max. @ 100 Hz -70 dBc/Hz max. @ 1 kHz -80 dBc/Hz max. @ 10 kHz
-90 dBc/Hz max. @ 100 kHz -100 dBc/Hz max. @ 1 MHz |
Input V.S.W.R. / Output V.S.W.R. | 2 : 1 max. / 1.5 : 1 max. |
DC Power Requirement
(1) Voltage Range (2) Power Consumption @No IF Signal @ Pout=+44dBm @ Psat |
+36 to +60 VDC 120 W typ. 220 W typ.
260 W typ., 290 W max. |
Mute | Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal |
M&C | Interface: FSK Communications Signal / RS-232C
Function: Power Monitor / TX On/Off Control / Alarm / Digital Step Attenuator … etc |
Temperature Range (ambient) Operating: Storage: | -40 to +60 °C
-40 to +75 °C |
Dimension & Housing | 230 (L) x 150 (W) x 100 (H) mm without interface connectors and screws |
Weight | 4.4 kg [9.1 lbs ] |
NJRC NJT8371NMR 40W GAN Standard Ku-Band Robust BUC Datasheet
NJRC NJT8371NMR 40W GAN M&C Specification